Figure 175. Installing the BOSS-N1 module blank
To install the BOSS-N1 module:
1. Install the BOSS-N1 module . To install the BOSS-N1 , see installing the BOSS-N1 module.
2. Install the M.2 SSD. To install the M.2 SSD, see installing M.2 SSD.
NOTE:
Installing the BOSS-N1 card carrier does not require the system to be powered off. System shutdown is only
required when installing the BOSS-N1 controller card module.
To remove the BOSS-N1 module:
1. Power off the system.
2. Remove the M.2 SSD. To remove the M.2 SSD, see removing the M.2 SSD.
3. Remove the BOSS-N1 module. To remove the BOSS-N1 controller card module, see removing the BOSS-N1 module.
4. Install the BOSS-N1 module blank.
NOTE:
Removal of the BOSS-N1 card carrier does not require the system to be powered off. System shutdown is only
required when removing the BOSS-N1 module.
NOTE: Disconnect the BOSS signal cable and the BOSS power cable before lifting the module from the system.
Data Processing Unit (DPU) kit
The channel or vendor DPU kit contains one 25G Network card. For installation procedure of Network card, see Installing an
expansion card into the expansion card riser section.
For more information about the supported channel DPU slots, See Expansion card installation Guidelines section.