Dell PowerEdge R6615 9JNDF - Installing the left control panel

Dell PowerEdge R6615 9JNDF
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 161. Removing the left control panel
Next steps
1. Replace the left control panel.
Installing the left control panel
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the drive backplane cover.
4. If installed, remove the air shroud.
5. Remove the cooling fan.
6. Remove the side wall bracket.
Steps
1. Align and slide the left control panel in the slot on the system.
2. Route the left control panel cable through the side wall of the system.
3. Connect the left control panel cable to the connector on the system board .
4. Align and slide the left control panel cable cover in the slot on the system.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
5. Using the Phillips #1 screwdriver, tighten the screws to secure the left control panel and the cable cover to the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
186 Installing and removing system components