ASDA-A2  Chapter 6  Control Mode of Operation 
Revision February, 2017  6-23 
 
Settings: 
The setting value of the second low-frequency vibration suppression. If 
P1-28 is set to 0, then it will disable the second low-frequency filter. 
 
P1-28 
 
VSG2  Low-frequency Vibration Suppression Gain (2) 
Address: 0138H 
0139H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section:  
6.2.9 
 
Default: 
0 
 
Control 
Mode: 
PT / PR 
 
Unit: 
- 
 
Range: 
0 ~ 9 (0: Disable the second low-frequency 
filter) 
 
Data Size: 
16-bit 
 
Format: 
Decimal 
 
Settings: 
The second low-frequency vibration suppression gain. The bigger value 
it is, the better the position response will be. However, if the value is set 
too big, the motor will not be able to smoothly operate. It is suggested to 
set the value to 1.