ASDA-A2  Chapter 12 Absolute System 
12-2     Revision February, 2017 
12.1   Backup Battery Boxes 
12.1.1   Specifications 
Precautions 
Please thoroughly understand and observe the following safety precautions. Failure to observe 
these precautions may void warranty! In order to prevent damage and danger, please use batteries 
in accordance with the specified specification.
 
 
  Do not use the product in a potentially explosive environment. Install the product in a 
clean and dry location free from corrosive and inflammable gases or liquids. 
  Do not place the battery dispersedly to prevent short circuiting and accidents. 
  Do not short circuit the positive pole and the negative pole of the batteries or install 
batteries in reverse polarity.  
  To prevent electric energy loss and lifetime reduction, it is recommended to use new 
batteries only. 
 
 
  Do not store batteries within an ambient temperature above +100°C. Failure to observe 
this precaution may cause fire or explosion.   
  The batteries are non-rechargeable. Do not charge the batteries or explosion may 
result. 
  Do not directly solder the battery surface.  
 
Battery Specifications 
Items  Li/SOCl2 Cylindrical Battery 
Type ER14505 
Delta Model Number  ASD-CLBT0100 
International Standard Size  AA 
Nominal Voltage  3.6 V 
Nominal Capacity  2700 mAh 
Maximum Continuous Operating Current  100 mA 
Maximum Pulse Current  200 mA 
Dimensions (D x H)  14.5 x 50.5 mm 
Weight Approx. 19 g 
Operating Temperature  -40 ~ +85°C