ASDA-A2  Chapter 7 Motion Control 
7-36     Revision February, 2017 
The diagram of CAP: 
 
 
7.11.2  Function Description of COMPARE (Data Compare) 
The concept of COMPARE is to compare the instant position of motion axis with the value which 
is saved in data array. Then output DO3 after the COMPARE condition is established for motion 
control. Since COMPARE is finished by hardware, there is no problem of software delay. It also 
can accurately compare the high-speed motion axis. The COMPARE features provided by this 
servo drive is as follows. 
COMPARE Features  
Pulse Source 
  Main Encoder of the Motor 
  Auxiliary Encoder (linear scale) 
  Pulse Command 
  CAP Axis (set by CAPTURE). When selecting this axis, CAP 
source cannot be changed. 
The selected axis is displayed in P5-57. Before compare, the 
default value can be written in. 
Output Signal 
  Output by DO4 and the response time is 5 usec. 
Note: DO3 directly connects to COMPARE hardware, thus, 
regardless the setting value of P2-20 (DO Code), the function 
can work. When using COMPARE, in order to avoid DO error, 
the system will force to disable DO function, which means the 
setting will be P2-21 = 0x0100 automatically. Since the value 
is not written into EEPROM, P2-21 will return to the default 
value after re-power on. 
Output Method 
  Pulse output can select contact A/B. 
  It is capable to continuously output more than one point. 
  It can set the pulse output time.