ASDA-A2  Chapter 7 Motion Control 
7-18     Revision February, 2017 
7.10   Parameter Settings 
1)  Target speed: P5-60 ~ P5-75, 16 PR in total 
Bit  15 ~ 0-bit 
W0  TARGET_SPEED: 0.1 ~ 6000.0(r/min)  
 
2)  Accel / Decel time: P5-20 ~ P5-35, 16 PR in total 
Bit  15 ~ 0 
W0  T_ACC / T_DEC: 1 ~ 65500 (msec)  
Note: The deceleration time used by DI: STP/EMS/NL(CWL)PL(CCWL) is defined via P5-07. 
 
3)  Pause time: P5-40 ~ P5-55, total 16 PR in total 
Bit  15 ~ 0 
W0 
IDLE:0 ~ 32767(msec)  
 
4)  PR parameters: P5-00 ~ P5-09, P6-00 ~ P6-01, 12 DWORD in total 
  32-bit 
P5-00  Reserved 
P5-01  Reserved (It is for testing only, do not use) 
P5-02  Reserved (It is for testing only, do not use) 
P5-03  Deceleration time of auto protection 
P5-04  Homing mode 
P5-05  1
st
 Speed setting of high speed homing 
P5-06  2
nd
 Speed setting of low speed homing 
P5-07  PR command register 
P5-08  Forward software limit 
P5-09  Reverse software limit 
P6-00  Homing setting 
P6-01  Origin definition 
          Note: Path (procedure) 
 
5)  PR Definition: P6-02 ~ P7-27, (64-bit), 63 sets of PR in total (2N)  
Bit  31 ~ 28  27 ~ 24  23 ~ 20  19 ~ 16  15 ~ 12  11 ~ 8  7 ~ 4  3 ~ 0 
DW0  …  …  …  …  …  …  …  TYPE 
DW1  DATA (32-bit) 
Each PR has two parameters; the PR function is determined by TYPE. DATA represents position 
or speed data while the others are the additional information.