ASDA-A2  Chapter 8  Parameters 
Revision February, 2017    8-37 
P0-52★ 
 
APP 
Encoder Absolute Position  
(Pulse number within Single turn or PUU) 
Address: 0068H 
0069H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: N/A 
 
 
Default: 
0x0 
 
Control 
Mode: 
ALL 
 
Unit: 
Pulse or PUU 
 
Range: 
0~1280000-1 (Pulse Number);  
-2147483648 ~ 2147483647 (PUU) 
 
Data Size: 
32-bit 
 
Format: 
Decimal 
Settings:While the Bit 1 of P2-70 is set to 1 to read the pulse number, this 
parameter represents the pulse number of encoder absolute position.  
While the Bit 1 of P2-70 is set to 0 to read the PUU number, this 
parameter represents PUU number of motor absolute position. 
 
P0-53    ZDRT 
General Range Compare Digital Output – 
Filtering Time 
Address: 006AH 
006BH 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: N/A 
 
 
Default: 
0x0000 
 
Control 
Mode: 
ALL 
 
Unit: 
ms 
 
Range: 
0x0000 ~ 0x000F 
 
Data Size: 
16-bit 
 
Format: 
Hexadecimal 
Settings: 
 
X: Filtering time for 1st monitoring variable 
UYZ: Reserved 
While the value of the monitoring variable is changed within the range 
between the setting values of P0-54 and P0-55, this parameter is used