ASDA-A2  Chapter 8  Parameters 
Revision February, 2017    8-95 
P2-08■ 
 
PCTL  Special Parameter Write-in 
Address: 0210H 
0211H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: - 
 
Default: 
0 
 
Control 
Mode: 
ALL 
 
Unit: 
- 
 
Range: 
0 ~ 65535 
 
Data Size: 
16-bit 
 
Format: 
Decimal 
 
Settings: 
Special parameter write-in: 
Parameter 
code 
Function 
10  Reset the parameter (Apply to the power again after reset) 
20  P4-10 is writable 
22 P4-11~P4-21are writable 
30,35  Save the data of COMPARE, CAPTURE, E-Cam 
406 
Enable forced DO mode 
400 
When forced DO mode is enabled, it can switch back to 
the normal DO mode. 
 
NOTE
 A2L does not support E-Cam function. 
 
P2-09    DRT  DI Debouncing Time 
Address: 0212H 
0213H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: - 
 
Default: 
2 
 
Control 
Mode: 
ALL 
 
Unit: 
ms 
 
Range: 
0 ~ 20 
 
Data Size: 
16-bit 
 
Format: 
Decimal 
 
Settings: 
When the environmental noise is big, increasing the setting value can 
enhance the control stability. However, if the value is set too big, the 
response time will be influenced.