Chapter 8  Parameters  ASDA-A2 
8-146     Revision February, 2017 
 
 
P1-47 10  EEPROM
 
 
P1-49 0  EEPROM
 
 
P1-38 100  EEPROM  
Home offset 
0  EEPROM  Used in HM 
mode 
P1-44 
1 
EEPROM
 
 
P1-45 
1 
EEPROM
 
 
 
DMCNET mode: 
Related variables 
during initialization 
P3-12.Z = 0  P3-12.Z = 1  Note 
P1-32 
0x0010 EEPROM
 
 
P2-35 
3840000
 
EEPROM
 
 
P1-47 
100 EEPROM
 
 
P1-49 
0 EEPROM
 
 
P1-38 
100 EEPROM
 
 
Home offset 
0  Undefined  Used in HM 
mode 
Acc 
200  Undefined  Used in PV, PP 
mode 
Dec 
200  Undefined  Used in PV, PP 
mode 
P1-44 
1 EEPROM
 
 
P1-45 
1 EEPROM
 
 
Methods that save parameters in EEPROM (even when the power is 
off): 
                             SDO: When setting parmeters, parameters will be stored in EEPROM. 
                             PDO: Please refer to the setting of P3-11.X 
  X = 1: When setting parameters via PDO, parameters will be stored in 
EEPROM. 
X = 0: When setting parameters via PDO, parameters will not be stored 
in EEPROM. 
Note: In CANopen mode, when using the funciton of OD 1010 Store 
Parameter and P3-12.Z = 0, the default value will be different from the value 
that showed above. Please refer to CANopen Standard for further information.