Chapter 8  Parameters  ASDA-A2 
8-224     Revision February, 2017 
 
Settings: 
Four items: UZYX 
When EVx is set to ON, the PR# will be executed. 
X=0: When EV1 is ON, PR will not be triggered. 
X=1~D: When EV1 is ON, execute PR # 51~63. 
Y=0: When EV2 is ON, PR will not be triggered. 
Y=1~D: When EV2 is ON, execute PR # 51~63. 
Note: EV3 and EV4 are supported after firmware V1.009. 
 
 
 
Z=0: When EV3 is ON, PR will not be triggered. 
Z=1~D: When EV3 is ON, execute PR # 51~63. 
U=0: When EV3 is ON, PR will not be triggered. 
U=1~D: When EV4 is ON, execute PR # 51~63. 
 
P5-99    EVOF  PR# Triggered by Event Falling-Edge 
Address: 05C6H 
05C7H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: - 
 
Default: 
0 
 
Control 
Mode: 
PR 
 
Unit: 
- 
 
Range: 
0000 ~ 0xDDDD 
 
Data Size: 
16-bit 
 
Format: 
Hexadecimal 
 
Settings: 
Four items: UZYX 
When EVx is set to OFF, the PR# will be executed. 
X=0: When EV1 is OFF, PR will not be triggered. 
X=1~D: When EV1 is OFF, execute PR # 51~63. 
Y=0: When EV2 is OFF, PR will not be triggered. 
Y=1~D: When EV2 is OFF, execute PR # 51~63. 
Note: EV3 and EV4 are supported after firmware V1.009. 
Z=0: When EV3 is OFF, PR will not be triggered. 
Z=1~D: When EV3 is OFF, execute PR # 51~63. 
U=0: When EV4 is OFF, PR will not be triggered. 
U=1~D: When EV4 is OFF, execute PR # 51~63.