DVP-ES3/EX3/SV3/SX3 Series Hardware and Operation Manual
CPU Error
Trigger sending an email if an error occurs in the CPU module. Refer to the Operation manuals for more information
about errors occurring in CPU modules. After you select CPU Error, select Fatal Error Only or All Errors in the list at
the right side of the option.
a) Fatal Error Only: Send an email if a fatal error occurs in the CPU module.
b) All Errors: Send an email if an error occurs in the CPU module.
CPU (RUN<=>STOP)
Trigger sending an email when the CPU module begins to run, or when the CPU module stops running.
Bit Status Change
Trigger sending an email if the state of a bit device specified meets a set condition. For example, if X0 switches from
OFF to ON, it triggers sending an email. To set a condition, click the
button in the following dialog box.
Device Name: Select a device type.
Device Number & Bit: Type a device address; if the device type selected is X/Y, you must specify a bit
number as well.
State: Select Rising or Falling.
Register Value Change
Trigger sending an email if the value in a device specified meets a set condition. For example, if the value in D0 is
larger than 10. To set a condition, click the
button in the following dialog box.