7-2
Ultron HPH Series
7.1 LCD Display Hierarchy
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
*
1
MEASUREMENT
UPS-1.1
SETUP
MAINTENANCE
EVENT LOG
LOG IN
(Level 3)
(Level 3) (Level 3) (Level 3) (Level 3) (Level 3) (Level 3)
(Level 3)
(Level 3)
(Level 3) (Level 3) (Level 3) (Level 3) (Level 3) (Level 3) (Level 3)
(Level 3) (Level 3) (Level 3) (Level 3) (Level 3) (Level 3) (Level 3)
(Level 1) (Level 1) (Level 1) (Level 1) (Level 1) (Level 1)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
(Level 2)
Power Flow
System Status
Main Input
Bypass Setting
Warning
Historical Event
Statistics
Test
Clear
Advanced
Diagnosis
Version & S/N
Mode Setting
Output Setting
Battery & Charging Setting
Parallel Setting
Dry Contact Setting
General Setting
IP Setting
Control
Bypass Input
Inverter Output
Power Module
Summary
UPS Output
Battery Status
Summary
Log-in ID:
Guest
Log-in ID:
Administrator
Input
Main Voltage
Bypass Voltage
Output
Frequency
Voltage
Current
Load
Output Power
Battery
Runtime Remaining
Voltage
Charge Current
System
STS Temp. (°C)
Battery Temp. (°C)
Fan Speed (rpm)
Power Module
INV Temp. (°C)
PFC Temp. (°C)
S/N
System
Touch Panel
Power Module#
MAIN
COM_MCU / FPGA
System_MCU / FPGA
Touch Panel_MCU / FPGA
INV
Power Module#_MCU / FPGA
PFC
Power Module#_MCU / FPGA
Phase Voltage (V)
Line Voltage (V)
Current (A)
Frequency (Hz)
Bypass Frequency Range/
Bypass Voltage (Max)/
Bypass Voltage (Min)/
ECO Voltage Range (±%)
Warning
Historical Event
In Battery Mode
Battery Mode Duration
In Bypass Mode
Bypass Mode Duration
Operation Time
Manual Battery Test
Clear Statistics
Clear Historical Event
Clear Battery Test Result
On-Line/ Green/ ECO/
Energy Recycle/
Frequency Conversion
Voltage (V) / Frequency (Hz) /
Slew Rate (Hz/s) /
PM Redundancy (V) /
Async Transfer Time (ms) /
Module Sequential Start (s) /
System Sequential Start (s)
Battery Type/ Battery Rating Voltage (V)/
Battery Strings/ Battery Low Warning/
Battery Cut Off Voltage/
Capacity (AH)/ Float Charge Voltage/
Equalized Charge Voltage/
Charge Current (Max)/
Auto Equalized Charge/
Auto Equalized Charge Interval/
Equalized Charge Time/
Battery Test Fail Voltage/
Battery Test Duration/
Auto Battery Test Interval/
Low Temperature Alarm(°C)/
High Temperature Alarm(°C)/
Installation Date/ Next Replacement Date
Parallel Group ID/ Parallel ID/
Common Battery
Phase Voltage (V)
Line Voltage (V)
Frequency (Hz)
Phase Voltage (V)
Line Voltage (V)
Current (A)
Frequency (Hz)
Phase Voltage (V)
Current (A)
DC BUS Voltage
PM A/D
PM D/D
Phase Voltage (V)
Line Voltage (V)
Current (A)
Frequency (Hz)
Load (%)
Apparent Power (KVA)
Active Power (KW)
Power Factor
Status/
Voltage (V)/
Current (A)/
Remaining Capacity (%)/
Remaining Time (mins)/
Estimated Recharging
Time (mins)
Test Result/
Battery Temp. #1 (°C)/
Battery Temp. #2 (°C)/
Battery Temp. #3 (°C)/
Battery Temp. #4 (°C)/
Charge Voltage/
of PM# (V)/
Charge Current
of PM# (A)
Input Dry Contact : 1 ~ 4
Output Dry Contact : 1 ~ 6
DHCP Client/ IP Address/
Subnet Mask/ Gateway IP/
DNS 1 IP/ DNS 2 IP/ Search Domain
Host Name
Buzzer
Force Equalized Charge/
Force Bypass to Inverter/
Reset Module/ Reset System
Date/ Time
Date Format/ Date/ Time
Screen
Screen Brightness/ Screen Sleep (after)
User
Language/ MODBUS ID/
Admin Password
Dust Filter
Dust Filter Installation/
Dust Filter Installation Date/
Dust Filter Replacement Date
(Figure 7-1: LCD Display Hierarchy)