Troubleshooting
31
Symptom Probable Cause Suggested Remedy
Door will not open Thermoactuator Check to see if thermoactuator(s) and/or its
mechanism is stuck or binding and not allowing
the door lock solenoid to open. Check to be sure
that the locking thermoactuator is not receiving
120VAC during the last 1 1/2 minutes of the
cycle. Also check to see that the unlocking
thermoactuator is receiving 120VAC during the
last minute of the cycle. If the thermoactuators do
not receive voltage at the correct times, change
the timer. If the timing and voltage are correct,
replace the thermoactuator.
Door Rod Check to see that door rod from solenoid to lock
ass’y is long enough to allow lock ass’y to
disengage. If not, adjust rod.
Door Lock Solenoid Check that door lock solenoid is not stuck closed.
If stuck, replace solenoid.
Door Locking Pawl Check to see if mechanical restriction at pawl
& Roll pins mounting pivot on door switch mounting plate.
Check that roll pins on door switch plate are not
cracked or broken and restricting door cam from
turning.
Hot water does Water Valve Coil Check coil continuity at terminals and replace if
not enter tub no continuity.
in wash
Water Inlet Check water inlet screens for blockage and clean
Screens if necessary.
Water Check to insure that water is turned on and
operating.
Programming Is hot water programmed?
Pressure Switch Check pressure switch continuity between
wired terminals . If no continuity, check
pressure switch hose for obstruction. If hose okay,
change pressure switch.