User Guide
ECB-VAVS Preloaded Applications

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Distech Controls ECB-VAVS and is the answer not in the manual?

Distech Controls ECB-VAVS Specifications

General IconGeneral
Controller TypeVariable Air Volume (VAV) Controller
ModelECB-VAVS
Communication ProtocolBACnet MS/TP
Supply Voltage24 VAC/DC
Enclosure RatingIP20
CommunicationRS-485
Power Supply24 VAC/DC
Operating Temperature0°C to 50°C (32°F to 122°F)
MountingDIN rail

Summary

Introduction

Introduction to the ECB-VAVS Preloaded Applications

Overview of preloaded VAV applications and controller configuration methods.

Applications Comparison Chart

Comparison of ECB-VAV, ECB-VAVS, and ECB-VAV-N models and configurations.

About This User Guide

Guide details purpose, audience, and conventions including mouse actions and abbreviations.

Sequence of Operation

Occupancy Control, Temperature Setpoints, and HVAC Modes

Explains controller operation for occupancy, temperature setpoints, and HVAC modes.

Airflow Control and Calibration

Details airflow control setpoints, calculation, and the VAV calibration process.

CO2 Sensor

Covers CO2 sensor priorities, control, and airflow setpoint calculation based on CO2 load.

Heat Control and Output Wiring

Describes heat control options, priority, shedding, and output wiring for heating.

VAV Performance Assessment Control Charts (VPACC)

Introduces VPACC for detecting unstable VAV operation and its benefits.

Receiving Network Values

Explains VAV controller network value reception and communication failure handling.

Using the dc gfxApplications

Accessing the Preloaded Applications with EC-Net Pro

Guide to accessing ECB-VAVS preloaded applications via EC-Net Pro and dc gfxApplications.

Configuring the VAV with EC-Net 4

Detailed steps for configuring VAV parameters like setpoints, flow, and damper via EC-Net 4.

Configuring the Preloaded Applications

Using Configuration Assistant for VAV setup: Overview, Hardware, HVAC, and Air Flow tabs.

Saving to Multiple Devices

Procedure for synchronizing and saving controller configurations to multiple devices.

Setting Up Trends

Enabling and viewing trends for space temperature and effective setpoint.

Allure EC-Smart-Vue Screen-by-Screen Guide

Adjusting the Setpoints and Display Units

Instructions for modifying setpoints and display units using the Allure EC-Smart-Vue sensor.

How to Put a Controller Into Bypass Mode

Step-by-step guide to changing controller occupancy mode to bypass mode.

General Configuration and Sensor Calibration

Entering general configuration, setting network parameters, and calibrating sensors.

Configuring the VAV

Configuring VAV parameters like box type, heat stages, and VVT mode.

Setting up Inputs

Configuring controller inputs, including input types and parameters.

Setting up Outputs

Configuring controller outputs, including heat types and wiring.

Configuring the Flow Setpoint Parameters

Setting airflow setpoints like min/max flow for different modes.

Performing VAV Airflow Balancing

Procedure for VAV airflow balancing, K-Factor, setpoint override, and damper initialization.

Performing Overrides

Performing damper and output overrides, and releasing active overrides.

Configuration Codes

Procedure for Submitting New Configuration Codes

Instructions on submitting configuration codes for VAV, Input, and Output configurations.

Tables of Configuration Codes

Reference tables for configuration codes for VAV, Input, and Output parameters.