44
EN
IP2163EN
Type of
alarm
Display Description Operation LED
Control panel
internal alarm
IA - Internal parameter error
(EEPROM)
Reset.
If the problem persists, replace the
control panel.
IB - Internal parameter error (RAM) Reset.
If the problem persists, replace the
control panel.
IC - Operation time out error (>5 min
or >7 min in acquisition mode)
Manually check that the door wing
moves freely.
If the problem persists, replace the
control panel.
IH - Overcurrent with motor
switched off alarm
Reset.
If the problem persists, replace the
control panel.
Control panel
internal alarm
IM - Shortcircuited motor MOSFET
alarm
Reset.
If the problem persists, replace the
control panel.
IO - Interrupted power circuit (mo-
tor MOSFET open)
Reset.
If the problem persists, replace the
control panel.
IR- Motor relay malfunctioning Reset.
If the problem persists, replace the
control panel.
XX - Firmware reset (SIGNAL ONLY)
Service
V0 - Request for maintenance inter-
vention
Proceed with the scheduled mainte-
nance intervention.
NO - Operation not permitted Check that the remote control has
not already been stored.
Check that the storage module is
present.