EasyManua.ls Logo

DMC Sigma2N - IPM Motor Error Subcodes

DMC Sigma2N
166 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Simga2N Traction Advanced Manual V1.3 Page 155 (166) ©2021 DMC GmbH Herten Germany
8.1.3 IPM motor error subcodes
Sub
Code
Description
0
No errors in the motor module
1
The motor module could not be initialized. Report to DMC
2
An overcurrent is detected: Motor is overloaded or wrong position sensor settings
3
Internal error Report to DMC
4
Wrong current: rated motor current is greater than maximum: Check setting 8 and 7 in the autotune
menu
5
Wrong poles number.
6
Internal error Report to DMC
7
Internal error Report to DMC
8
Sine signal is out of range: check connection and sensor
9
Cosine signal is out of range: check connection and sensor
10
No Hall sensor signal; check connection and sensor
11
Unable to perform recalculation: motor calculated maximum speed exceeds 500 Hz: ; check motor
parameters (LD,LQ Ke, Fmax) in auto tune menu.
12
Unable to perform recalculation: two or more speed points are equal. The maximum current set is
too high for the motor. Decrease the Maximum current in the Autotune menu and perform a
recalculation.
13
In one point or several points of the tables the total current (Sqrt(Id^2+Iq^2)) exceed the maximum
current set in the autotuning menu. Current Tables are not consistent with autotuning menu.
How to eliminate this error:
1) Do a recalculation procedure
2) Set in advanced Motor menu “ Angle/Idq Table Control “IDQTblCn”” to 0 and if it is possible
do motor autotuning again (full type or type 2). Set back “ Angle/Idq Table Control “IDQTblCn”” to 1
once autotuning succeed.
14
Sensor number of poles is inconsistent with motor poles. Possible combination of Motor poles and
sensor poles are the ones give integer ratio between NMotorPole/NSensPole.
Example: NMotorPoles 8 NSensorPoles 4 ratio= 2 (8/4) allowed
NMotorPoles 8 NSensorPoles 6 ratio= 1,33 (8/6) NOT allowed
15
Internal error Report to DMC,

Table of Contents