Simga2N Traction Advanced Manual– V1.3 Page 144 (166) ©2021 DMC GmbH Herten Germany
8 Diagnostics
8.1 Error Codes
The following tables describe all the error codes that the controller will display. The presence of an error can be
detected by means of a red led flashing on controller (number of flashes correspond to base error code) and
investigated in “Menu 0 “Status””
The error codes are divided in four different categories, based upon the severity of the faults.
Controller warning faults - Reduces only performance - Fault will reset itself (if possible)
Battery voltage below absolute minimum
Capacitor voltage below absolute minimum
Battery voltage below LV cut back adjustment (drive cut back active)
Capacitor voltage below LV cut off adjustment (drive cut back active)
Inhibit drive/ BDI Cut /
BLC via can
BDI Cut out (Battery below BDI cut Level)
Pump inhibit input active (Only Pump Software)
BCL via CAN message time out
BCL via CAN message toggle security bit fail
BMS timeout after initialization
Battery voltage above absolute minimum
Capacitor voltage above absolute minimum
Battery voltage above High Voltage cut back adjustment (brake cut back
active)
Capacitor voltage above High Voltage cut back adjustment (brake cut back
active)
Controller temperature
high
Master does not share the line contactor but any one of the slave does
Master shares the line contactor but one of the requested slave doesn’t
WigWag is enabled but walkie is not
Inching and walkie are both enabled
Both AI2 and AI3 are setup with the same function
Inching and Control Via CAN HMI both active
Walkie and Control Via CAN HMI both active
Hill hold Enabled and Torque control enabled
Can Node ID via digital input enabled but control but Control Via CAN HMI
is not enabled.