7 Monitoring
Menu 0 “Status”
The status menu shows various parameters from the controller which can be useful to help tune and optimize vehicle’s
performance. By pressing the decrement ( ) or the increment ( ) button on the calibrator extra information about
the selected status variable are displayed.
Cal.
Ref.
Item
Calibrator
text
Step
size
Service log info & Notes
1
Drive hours counter
Drive
0.1 Hrs
shows key hours
2
Current Fault code
CurFault
Fxx
Show fault time
Sub code
3
Battery Discharge
Indicator
BDI
1 %
Raw BDI value incl. state
(WO & CO)
BDI states
(see M0-1 BDI
States table”)
4
Controller
Temperature
CtrlTmp
0.1 C
Min. temperature
Max. temperature
5
Motor
Temperature
MotTemp
0.1 C
Shows N/A when disabled.
Min. temperature
Max. temperature
6
Drive State
DriveSta
--
See “M0-2 Drive and brake status table
7
Speed Limit
SpeedLim
--
See “M0-3 Speed limits table
8
Torque Limit
TrqLimit
--
See “M0-4 Torque limits table
9
Motor Limit
MotorLim
--
See “M0-5 Motor limits table
10
Battery Voltage
BatVolts
0.1 V
Max. Voltage
11
Capacitor Voltage
CapVolts
0.1 V
Max. Voltage
12
Battery current
I_batter
0.1 A
13
DS301 status
DS301Sts
--
See “M0-6 DS301 status table
14
DS402 status
DS402Sts
--
See “M0-7 DS402 status table
15
Motor current
I_Motor
0.1
Arms
Id Current
Iq Current
16
Motor voltage
V_Motor
0.1
Vrms
Reactive Power
Motor Power
Reached maximum
output voltage (VL)
17
Stator speed
StatorSpd
0.1 Hz
18
Rotor speed
RotorSpd
0.1 Hz
RPM speed
19
Accelerator
demand
Accel
0.1 %
Steer pot demand
Foot brake demand
20
Target demand
DemTrgt
0.1 %
+
CW
CCW
21
Ramped demand
DemRampd
0.1 %
+
CW
CCW
22
Speed limit %
23
Drive torque limit
DrvTrqL
0.1 %
Torque limit CW
24
Brake torque limit
BrkTrqL
0.1 %
Torque limit CCW
25
Actual torque
TrqAct
0.1 %
Actual torque in Nm
Maximum torque in
Nm
+
CW
CCW
26
Actual speed
SpeedAct
0.1 %
+
CW
CCW
27
Actual Flux
FluxDem
0.1 %
Actual Flux
28
Filtered capacitor
voltage
29
Vehicle Speed
Vehicle
1 Kph
30
Motor RPM speed
RPMspeed
1 rpm
To reset the max and min temperatures logged data, press the + and button at the same time