M5.2-6 Sensor resistance at temperature 1 “Res at T1
M5.2-7 Motor temperature 1 “MTemp1”
M5.2-8 Sensor resistance at temperature 2 “Res at T2
M5.2-9 Motor temperature 2 “MTemp2”
M5.2-10 Sensor resistance at temperature 3 “Res at T3”
M5.2-11 Motor temperature 3 “MTemp3”
M5.2-12 Sensor resistance at temperature 4 “Res at T4”
M5.2-13 Motor temperature 4 “MTemp4”
M5.2-14 Sensor resistance at temperature 5 “Res at T5”
M5.2-15 Motor temperature 5 “MTemp5”
Those parameters are visible only if M5.2-1 Motor temperature sensor type “MtempTyp”” is set to 3. They
define the Resistance/Temperature curve in 5 points for a temperature sensor connected that is not covered
by the controller built in sensor types 0-1-2.
The curve might cover both “classical” and NTC (Negative Thermal Coefficient) thermal sensors. The sensor
type will be automatically detected and managed by the entered curve. Please notice that it is only possible to
enter only either ALL increasing resistance values (for classical thermal sensors) or ALL decreasing resistance
values (for NTC thermal sensors).