SuperSigma2 AM PMS – V1.5.6 17-1-2020 Page 94 (97) ©2019 DMC GmbH Herten Germany
12.2 PMS Motor sub error codes
No errors in the motor module.
The motor module could not be initialized.
An overcurrent is detected
Internal error refer to DMC
Wrong current: rated motor current is greater than max
Wrong poles number (is odd)
Wrong settings: rated motor voltage is too high in relation with the battery voltage capability. Check battery
voltage set in autotuning menu. Load defaults and reparmetrize
Internal error refer to DMC
Internal error refer to DMC
Sine signal is out of range: check connection and sensor
Cosine signal is out of range: check connection and sensor
No Hall sensor signals; check connection and sensor
Unable to perform recalculation: motor calculated maximum speed exceeds 500 Hz. Check motor
parameters.
Unable to perform recalculation: limit curves; check motor parameters (Ls, Ke, Fmax, Idemag) in auto tune
menu.
Unable to calculate controller gains: check motor parameters (Ls, Ke, Fmax, Idemag) and perform
recalculation or do autotuning again.
Internal error refer to DMC