XR2400F Product Specifications
13.1 Power supply
Transformer Input: 16.5 VAC 100VA
Standby Battery: 12 VDC 28Ah (100VA charges up to four batteries)
Auxiliary: 12 VDC output at 1 Amp
Bell Output: 12 VDC at 1.5 Amp
All circuits are inherent Power Limited except the red battery wire.
13.2 Communication
Built-in dialer communication to DMP Model SCS-1 Receivers
Built-in multiplex communication to DMP Model SCS-1 Receivers
Built-in Contact ID communication to non-DMP receivers
Built-in Modem IIe communication to non-DMP receivers
893A Dual Phone Line Modules with phone line supervision
Can operate as a local panel
13.3 Panel zones
Eight 1k Ohm EOL grounded zones (zones 1 to 8). Connect to 869 class A module or burglary applications.
Two 3.3k Ohm EOL Class B (Style A) powered zone with reset (zones 9 and 10)
13.4 Remote Annunciator
You can connect up to seven of the following supervised keypads or expanders to the XR2400F keypad data
bus:
• Alphanumeric Fire Command Centers or keypads
• Four and single point zone expanders
• Single point detectors
13.5 LX-Bus™
You can connect the following devices to the LX-Bus provided by the DMP 462N (supplied), 462P, 472, and/or
481 Interface Cards up to the maximum number of LX-Bus addresses. See Accessory Devices.
• Model 521LX or 521LXT Smoke Detectors with CleanMe
• Sixteen, eight, four, and single point zone expanders
• Relay output expanders
• Graphic annunciator modules
• Single point detectors
13.6 Outputs
Two SPDT relay outputs (requires two Model 305 relays that are provided on the panel, each rated 1 Amp at 30
VDC resistive). Connect only power limited sources to the relay.