Compliance
27
XR2400F Installation Guide
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
UNIVERSAL UL BURGLARY SPECIFICATIONS
25.1 Introduction
The programming and installation specifications contained in this section must be completed when installing the
XR2400F panel in accordance with any of the UL burglary standards. Additional specifications may be required
by a particular standard.
25.2 Wiring
All wiring must be in accordance with NEC, ANSI/NFPA 70, UL 681, and UL 611 for all burglary installations.
25.3 Control outside of protected area
A Potter EVD or Sentrol 5402 should be used in place of a lined cabinet when the panel is installed outside of
the protected area.
25.4 Police station phone numbers
The digital dialer telephone number programmed for communication must not be a police station phone number,
unless that phone number is specifically provided for that purpose.
25.5 Bypass reports
The Bypass Reports option must be programmed as YES for all UL burglary applications. See section 6.4 of the
XR200 and XR2400F Programming Guide (LT-0196).
25.6 System maintenance
Proper installation and regular maintenance by the installing alarm company and frequent testing by the end
user is essential to ensure continuous satisfactory operation of any alarm system. Offering a maintenance
program and acquainting the user with the correct procedure for use and testing of the system is also the
responsibility of the installing alarm company.
25.7 Partitions
The partition option may only be used for UL burglary applications when all partitions are used for one
subscriber. See section 4.2 and 11.2 of the XR200 and XR2400F Programming Guide (LT-0196). The panel
must be tamper protected and Sentrol Model 5402 or Potter EVD listed vibration detectors should be used.
25.8 UL Listed Receivers
UL has verified operation with the DMP SCS-1, Sur-Gard SG-HLR2-DG, FBII CP220PB, Osborne-Hoffman
Quick-Alert, and Radionics D6500 receivers.
UL 1023 SPECIFICATIONS
Household Burglar-Alarm System Units
26.1 Bell cutoff
The Bell Cutoff time cannot be less than five minutes. See section 8.2 of the XR200 and XR2400F
Programming Guide (LT-0196).
26.2 Entry delay
The maximum entry delay used must not be more than 45 seconds. See section 7.3 of the XR200 and XR2400F
Programming Guide (LT-0196).
26.3 Exit delay
The maximum exit delay used must not be more than 60 seconds. See section 12.4 of the XR200 and XR2400F
Programming Guide (LT-0196).
26.4 Weekly test
The product should be tested weekly.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR2400F and is the answer not in the manual?

DMP Electronics XR2400F Specifications

General IconGeneral
BrandDMP Electronics
ModelXR2400F
CategoryControl Panel
LanguageEnglish

Related product manuals