1
Introduction
XR2400F Installation
Guide
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
Introduction
1.1 Overview
The DMP XR2400F Addressable Fire Alarm Control Panel (FACP) is an expandable 24 VDC Fire Alarm Control
with built-in DACT and LCD Fire Command Center keyboard with membrane keyswitch. A complete system
can provide a total of 494 programmable inputs and outputs for commercial and industrial fire alarm service.
The 24 VDC 4 Amp notification appliance power is distributed between two class B style W NAC outputs.
Additional NAC outputs can be added with conventional supervision modules or addressable power supply/
boosters. Addressable smoke detectors and input modules round out the XR2400F to deliver a truly flexible and
expansive fire detection and notification system. The Fire Alarm Control Panel is shipped pre-wired in a red
metal enclosure housing the necessary components to monitor and control fire alarm notification appliances.
1.2 System Components
The XR2400F FACP consists of the following components:
• One Model XR2400F Command Processor panel • One Model 893A Dual Phone Line module
• Two Model 866 Class B Style W NAC modules • One Model 630F PCB and membrane switch
• One Model 504-24 VDC Power Supply • One 28 VAC transformer, TF-0030
• One 100 VAC transformer, TF-0015 • One Model 462N LX-Bus Expansion Card
• Two Model 305 Relays
1.3 Power Specifications
Command Processor:
Transformer Input of 16.5 VAC 100 VA
Standby battery of 12 VDC 30.8Ah (100VA charges up to four 7.7Ah batteries)
Auxiliary power of 12 VDC at 1 Amp
NAC Output of 12 VDC at 1.5 Amp
All circuits are inherent Power Limited except red battery wires.
NAC Output:
24 VDC 4 Amps shared between NACs 1 and 2
1.4 Before you begin
Before installing the XR2400F, we recommend you read through the entire contents of this guide. Familiarize
yourself with the features of the panel and the key points to remember during the installation. Be sure to read
and understand all of the caution statements printed in bold italics.
1.5 About this guide
The information in this guide is organized into five sections: Table of Contents, Introduction, Installation,
Compliance, and System Wiring Diagrams.
• The Table of Contents at the front lists the headings and subheadings used throughout each section of
the guide.
• The Introduction section gives you an overview of the XR2400F and this document.
• The Installation section begins with mounting instructions for the enclosure. Wiring diagrams for each
component also appear in this section.
• The Compliance section lists all UL listings the XR2400F currently follows.
• The System Wiring Diagrams provide illustrations of typical XR2400F systems.
Caution notes
Throughout this guide you will see caution notes containing information you need to know when installing the
XR2400F panel. These cautions are written in
bold and italics.
Failing to follow the caution note may cause
damage to the equipment or improper operation of one or more components in the system.
1.6 How to use this guide
To locate information about the installation of the XR2400F, go to the Table of Contents at the front of this
guide. Find the subject heading that best describes the information you need and turn to the section number
shown to the right of the heading. If you cannot find the information you need under that heading, scan through
a few of the headings and read the text under those that sound similar.