Symptom:
DRIVER WINDOW UP OUTPUT SHORT TO GROUND
When Monitored and Set Condition:
DRIVER WINDOW UP OUTPUT SHORT TO GROUND
When Monitored: Whenever the ignition is in the Run or Accessory position.
Set Condition: When the BCM turns on the Driver Window Up circuit and detects a
voltage of less than 0.5 volts for over 125 milliseconds, this code will set.
POSSIBLE CAUSES
DTC PRESENT
MOTOR SHORTED
DRIVER WINDOW UP DRIVER WIRE SHORT TO GROUND
BODY CONTROL MODULE -DRIVER WINDOW UP DRIVER SHORTED
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, erase DTCs.
Cycle the ignition switch from Off to Run.
Try to operate the Driver Window Motor by using the Driver Window Switch.
With the DRBIIIt, read DTCs.
Does the DRBIIIt display DRIVER WINDOW UP OUTPUT SHORT TO GROUND?
All
Yes → Go To 2
No → The condition that caused the code to set is not present at this
time. Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the Driver Window Motor connector.
Turn the ignition on.
With the DRBIIIt, erase DTCs.
Cycle the ignition switch from Off to Run.
Press the Driver Window Switch UP several times.
With the DRBIIIt, read DTCs.
Does the DRBIIIt display DRIVER WINDOW UP SHORTED TO GROUND?
All
Yes → Go To 3
No → Replace the Window Motor.
Perform BODY VERIFICATION TEST - VER 1.
347
POWER WINDOWS