EasyManua.ls Logo

Dodge ZB 2005 - Passenger Door Lock Circuit Short to Ground

Dodge ZB 2005
1873 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Symptom:
PASSENGER DOOR LOCK CIRCUIT SHORT TO GROUND
When Monitored and Set Condition:
PASSENGER DOOR LOCK CIRCUIT SHORT TO GROUND
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage on the passenger door switch mux circuit
below 0.7 volts for over 10 seconds.
POSSIBLE CAUSES
DTC PRESENT
PASSENGER DOOR SWITCH MUX CIRCUIT SHORT TO GROUND
PASSENGER DOOR LOCK SWITCH SHORT TO GROUND
PASSENGER INTERIOR DOOR HANDLE SWITCH SHORT TO GROUND
PASSENGER EXTERIOR DOOR HANDLE SWITCH SHORT TO GROUND
PASSENGER DOOR SWITCH MUX WIRE SHORT TO THE DRIVER DOOR SWITCH RETURN.
BODY CONTROL MODULE - PASSENGER DOOR SWITCH MUX CIRCUIT SHORT TO GROUND
TEST ACTION APPLICABILITY
1 NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIIIt, record and erase DTC’s.
Cycle the ignition switch from ON to OFF to ON.
With the DRBIIIt, read DTC’s.
Lower the passenger door window.
Remove the key and operate all the passenger door switches several times while
monitoring the DRBIIIt.
Wait 10 seconds.
Does the DRBIIIt display PASSENGER DOOR LOCK CIRCUIT SHORT TO
GROUND?
All
Yes Go To 2
No Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the Body Control Module C3 and C4 connectors.
Measure the resistance between ground and the Passenger Door Switch Mux circuit
in the BCM C3 connector.
Is the resistance below 300.0 ohms?
All
Yes Repair the Passenger Door Switch Mux circuit for a short to
ground
Perform BODY VERIFICATION TEST - VER 1.
No Go To 3
310
POWER DOOR LOCKS/RKE

Table of Contents

Related product manuals