EDLE Parameter A. standard
Parameter Function
Factory
setting
Adjustment range Para. Requirement
So Opening speed Swing door opening speed.
°/s
Note 
°/s - °/s
°/s max.
L.E. mode
.
Opening
Doors shall open from closed to back check or
°, whichever occurs first, in  seconds or
longer as required in Table I.
Total opening time to ° shall be as in Table II.
If door opens at more than °, iit shall
continue at the same rate as back check
speed.
bc Back check
Checking or slowing down of
door speed before door being
fully opened.
° ° - ° . Back check shall not occur before ° opening.
Sc Closing speed
Swing door closing speed,
automatic mode.
°/s
Note 
°/s - °/s
°/s max.
L.E. mode
.
Closing:
Doors shall close from ° to ° in  seconds
or longer as required in Table I.
Doors shall close from ° to fully closed in not
less than . seconds.
dd
Hold open
time
Hold open time.  s  s -  s .
Time delay:
When powered open, the door shall remain
open at the fully opened position for not less
than  seconds.
Exception: when push-pull activation is used,
the door shall remain at the fully opened
position for not less than  seconds.
hS
Support for manual mode in
door closed position.
.
hA
Adjustment, door activation
angle.
hF Power assist function.
Fo
Static force
in opening
direction
Static force on door closing
edge in opening direction.
. lb f
[ N]
. lb f [ N] -
 lb f [ N]
.
Force required to prevent a stopped
door from opening or closing shall not
exceed  lb f [ N] measured "
[.] from latch edge of door at any
point during opening or closing.
Fc
Static force
in closing
direction
Static force on door closing
edge in closing direction.
. lb f
[ N]
. lb f [ N] -
 lb f [ N]
.
The following table references portions of content from ANSI/BHMA A.. Refer to the standard, available
through ANSI or BHMA for additional information. Standard material reprinted with BHMA permission.
.. Door measurements, low energy power operated door.
Note : Speed may be slower after learning cycle