22
ED100LE 02-2021DL4616-001
dormakaba ED100LE operator – Fine cover
Installation Instructions
Chapter 8
. Customer Vac connection to mounting plate terminal block
TIGHTEN MAINS TERMINAL TO 5-7 in-lb
Use Copper Conductors ONLY
.. Customer Vac wiring.
WARNING
Routing and connection of 115 Vac
wiring to ED100LE must be
performed by a qualified person!
WARNING
115 Vac branch circuit disconnect or
circuit breaker must be OFF!
CAUTION
Use copper conductors only!
.. EDLE wiring options.
. Conduit box CB (Fig. ..).
• U/L approved conduit box accessory;
provides Vac surface wiring to
EDLE.
• Reference Para. .. for CB box
installation.
. Power cord wiring kit PC (Fig. ..).
• Eliminates need for hard wiring.
Permits EDLE to plug directly into
Vac receptacle.
• Power cord length: " from end of
conduit box to center of plug.
CAUTION
Insure PC installation conforms to
local and national electrical codes.
1 115 VAC terminal
block
2 Ground terminal
3 Mains terminal
torque and wire label
5 M3.5 screw
6 115 Vac plug to
operator
L 115 Vac
N Neutral
G Ground
Fig. 8.3.1 115 VAC terminal block
Fig. 8.3.2 Mains terminal torque and wire
label
Use Copper Conductors ONLY
1
2
3
6
L
N
G
Fig. 8.3.4 PC wiring kit HK3597-010
1 Power cord
HX3500-001
2 Wire nut
HX1429-010
3 Cord grip
HX3502-001
4 Conduit box
HX3501-001
5 120 Vac label
DD3597-001
Instruction manual,
power cord kit
DL3597-001
Fig. 8.3.3 CB conduit box
4 Conduit box
HX3501-001
4 11/16”
[119]
2 3/4”
[70]
4
1
2
3
4