Installation
Dimensions of the duct
Wall thickness 4 mm / 0.15’
–Diameter 100 mm / 4’’
5.1.2.2 Duct Mount Kit Polytron
®
87x0 IR
For installation instructions refer to 9033236.
Dimensions of the duct
–Diameter 200 mm / 8’’
rectangular cross-section 170 x 170 mm / 6.7" x 6.7".
5.2 Electrical installation
For recommended tightening torques and admissible wire specifications see
17 Technical data.
4482844827

Table of Contents

Other manuals for Dräger Polytron 8000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Polytron 8000 Series and is the answer not in the manual?

Dräger Polytron 8000 Series Specifications

General IconGeneral
Ingress ProtectionIP66/67
Detection PrincipleElectrochemical, Infrared, Catalytic Bead
Gases DetectedCombustible gases, toxic gases, and oxygen
DisplayLCD with backlight
Humidity Range0 to 99% RH (non-condensing)
Housing MaterialStainless steel
Output Signal4-20 mA, HART, RS-485 Modbus
Power Supply10 to 30 V DC
CertificationsATEX, IECEx, CSA
Temperature Range-40 °C to +65 °C (depending on sensor)