EasyManuals Logo

DSC Neo User Manual

DSC Neo
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
Section 5: Programming
[305] Panel Events 5
3/4 PGM 2 2-Wire Trouble/Restore
This reporting code is transmitted when a trouble condition on PGM 2, configured as two-wire smoke, occurs or is restored.
This reporting code is sent to the System Maintenance call direction group.
[311] Maintenance Events 1
1/2 RF Jam Trouble/Restore
Sent when RF jam troubles occur/are restored. The following events cause RF jam troubles:
l Wireless repeater jamming
l RF jam
3/4 Fire Trouble/Restore
Sent when a low sensitivity, tamper or internal fault condition/restore is detected on a wireless smoke detector.
5 Cold Start
Sent when power is restored to the alarm system after total power failure. The code is sent after 2 minutes to allow the alarm
controller to stabilize.
6 Delinquency
When the Delinquency option is off (page 103), this code is transmitted if the alarm system has not been armed for the num-
ber of days programmed in the Delinquency Transmission Delay (page 108).
When the Delinquency option is on, this code is transmitted when no zone activity has been detected on the system for the
number of hours programmed in Delinquency Transmission Delay.
7 Self Test Trouble
Sent when a self test trouble occurs for an outdoor PIR.
8 Self Test Trouble Restore
Sent when a self test trouble has been restored for an outdoor PIR.
[312] Maintenance Events 2
1/2 Installer Lead In/ Lead Out
The Installer Lead In and Lead Out reporting codes are sent when the alarm system enters and exits Installer Programming
respectively.
When Installer Programming is automatically exited after PC-Link is activated, the Installer Lead Out event is not com-
municated until after the DLS session is complete.
3/4 DLS Lead In/Lead Out
The DLS Lead In reporting code is sent:
l after DLS communication has been successfully established, but before the alarm system calls back the down-
loading computer. This code is only transmitted when call back is enabled.
l on user-initiated call-up.
The DLS Lead Out reporting code is sent when a DLS session is successfully ended.
Note: If DLS is terminated by an alarm, the DLS Lead Out reporting code is not transmitted.
5/6 SA Lead In/Lead Out
The SA Lead In reporting code is sent:
l after SA communication has been successfully established, but before the alarm system calls back the downloading
computer. This code is only transmitted when call back is enabled.
l on user-initiated call-up.
The SA Lead Out reporting code is sent when an SA session is successfully ended. The SA Lead Out reporting code is still
sent if the session is terminated by an alarm.
7 Event Buffer 75% Full
Sent when the event buffer reaches a threshold of 75% without being uploaded.
[313] Maintenance Events 3
1/2 Firmware Update Begin/was Successful
Sent when a remote firmware update is initiated/ is successfully completed.
- 103 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes

Related product manuals