Section 5: Programming
3 Firmware Update Fail
Sent after an unsuccessful remote firmware update.
[314] Maintenance Events 4
1/2 Gas Trouble/Restore
Sent when a trouble occurs or is restored on a wireless gas detector.
3/4 Heat Trouble/Restore
Sent when a heat trouble occurs or is restored on a wireless temperature detector.
5/6 Freeze Trouble/Restore
Sent when a freeze trouble occurs or is restored on a wireless temperature detector.
7/8 Probe Disconnected Trouble/Restore
Sent when a probe disconnected trouble occurs or is restored on a wireless temperature detector.
[321] Receiver Events
2/4/6/8 Receiver 1 - 4 FTC Restore
Sent when the panel detects an FTC trouble.
[331] Module Events 1
1/2 Module AC Trouble/Restore
This reporting code is transmitted when a modules AC supply fails or has been restored. A programmable delay applies to
both the trouble and the restore. This reporting code is sent to the System Maintenance call direction group.
3/4 Module Battery Trouble/Restore
These reporting codes are transmitted when a modules battery voltage falls below 11.5VDC or is restored. These reporting
codes are sent to the System Maintenance call direction group.
5/6 Module Battery Absent/Restore
These reporting codes are transmitted when a modules battery is detected as absent or restored. These reporting codes are
sent to the System Maintenance call direction group.
[332] Module Events 2
1/2 Module Low Voltage Trouble/Restore
Sent when module voltage drops below acceptable levels or is restored.
3/4 Module Supervisory Trouble/Restore
Sent when communication with a module is lost or restored.
5/6 Module Aux Trouble/Restore
Sent when a high current output module or power supply module experiences an auxiliary voltage supply trouble.
[335] Module Events 5
1/2 Output 1 Fault/Restore
This reporting code is sent when the first output on the high-current output expander module goes into fault (open or short)
or is restored.
Only the first output on the high-current expander module is supervised.
[351] Alternate Communicator 1
1/2 Alt. Comm Communications Fault/Restore
Sent when the system loses or restores communications with the alternate communicator.
3/4 Not used
5/6 Not used
7/8 Alt. Comm Radio/SIM Failure/Restore
Sent when the alternate communicator experiences trouble or restore of the radio/SIM.
[352] Alternate Communicator 2
1/2 Alt. Comm Network Fault/Restore
Sent when the alternate communicator loses or restores communication with the network.
5/6 Alt. Comm Ethernet Trouble /Restore
Sent when the alternate communicator detects a network absent condition or DHCP failure or restore.
- 104 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes

Related product manuals