EasyManuals Logo

DSC Neo User Manual

DSC Neo
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Section 5: Programming
[354] Alternate Communicator 4
Receiver 1 to 4 Trouble and Restore
Sent when the alternate communicator detects a trouble or restore condition on receiver 1-4.
1/2 Receiver 1 Trouble/Restore
3/4 Receiver 2 Trouble/Restore
5/6 Receiver 3 Trouble/Restore
7/8 Receiver 4 Trouble/Restore
[355] Alternate Communicator 5
Receiver 1 to 4 Supervision Failure and Restore
Sent when the alternate communicator detects a supervision trouble for the Ethernet receiver (1, 2) or the GPRS receiver (3,
4).
1/2 Receiver 1 Supervision Failure/Restore
3/4 Receiver 2 Supervision Failure/Restore
5/6 Receiver 3 Supervision Failure/Restore
7/8 Receiver 4 Supervision Failure/Restore
[361] Wireless Device Events
1/2 Wireless Device AC Failure/Restore
These options are used to enable wireless device AC failure/restore reporting codes. These reporting codes are sent when
a wireless device experiences an AC failure/restore.
3/4 Wireless Device Low Battery Trouble/Restore
These options are used to enable wireless device low battery trouble/restore reporting codes. These codes are sent when a
wireless device experiences a low battery trouble/restore.
5/6 Wireless Device Fault/Restore
These options are used to enable wireless device fault/restore reporting codes. This reporting code is sent when a wireless
device experiences a supervisory fault.
[401] System Test Events
1/2 Walk Test Start/End
Sent when installer walk test is initiated and terminated.
These reporting codes are in addition to the alarm reporting codes for the zones that are tripped during the walk test period,
if configured in section "[382] Communicator Option 3" on page 111.
3 Periodic Test Transmission
Sent when the test transmission programmed in section "[401] System Test Events" on page 105 occurs.
4 Periodic Test Transmission with Trouble
Sent when any of the following trouble conditions are present during a periodic test transmission:
l Fire Zone Trouble
l Battery Trouble
l Fire Zone Alarm (2-Wire Smoke)
l Aux Trouble
l Fire Trouble
l Bell Trouble
l Fire Tamper/Low Sensitivity (WLS)
l Module Supervisory
l Fire Zones Bypassed
l Ground Fault
l Fire Supervisory (Wireless)
l TLM Trouble
l AC Trouble
l FTC Trouble
This reporting code is sent in place of the standard Periodic Test Transmission code.
- 105 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes