29.6.1 Menu item output test
Attention: Danger of breakage !
The switching of output elements can lead to collisions
with other machine elements as well as to damages to the
automatic buttonholer.
Before switching on an output element make sure that this cannot
collide with other components.
Caution: Danger of injury!
Exercise utmost caution when making the output test with
the machine running.
In this menu the individual output elements can be engaged.
–
Select the desired output element with the keys “ñ”or“ò”.
The current status is shown in the display:
0 = Output inactive
1 = Output active
–
Press key “OK”.
The output is converted.
Output Designation
Y01 Needle thread trimmer, with 580-112000 and 580-312000
additionally looper thread cutter
Y02 Looper thread tension
Y03 Fabric clamp
Y04 Spreading
Y05 Needle thread puller
Y06 Cutter
Y07 Cutter
Y08 Looper thread pulling, only 580-121000/ 580-321000
Y09 Needle thread catcher (material)
Y10 Open the needle thread catcher
Y11 Needle thread catcher (needle)
Y12 Looper thread cutter, only 580-121000 /
580-141000/ 580-321000
Y13 Knife Multiflex, only 580-312000/ 580-321000
Y14 Cutting block Multiflex, only 580-312000/ 580-321000
Y15 Cutter
–
Quit the output test with key “ESC”.