30. Error messages
Error Info/Description Remedy
1051 Sewing motor timeout
· Cable to the sewing motor
reference switch faulty
· Reference switch defective
· Exchange the cable
· Exchange the reference switch
1052 Sewing motor excess current
· Cable of sewing motor faulty
· Sewing motor defective
· Control defective
· Exchange the sewing motor cable
· Exchange the sewing motor
· Exchange the control
1053 Too high mains voltage
Check mains voltage
1055 Sewing motor overcharge
· Sewing motor blocked/moves
too heavy
· Sewing motor defective
· Control defective
· Eliminate the blocking/rough
running
· Exchange the sewing motor
· Exchange the control
1056 Sewing motor excess
temperature
· Sewing motor moves too
heavy
· Sewing motor defective
· Control defective
· Eliminate the rough running
· Exchange the sewing motor
· Exchange the control
1058 Sewing motor speed
Sewing motor defective
· Exchange the sewing motor
1062 Sewing motor IDMA
Autoincrement
Malfunction
Switch the machine off/on again
1302 Sewing motor: current supply
fault
Encoder cable not connected /
defective
Encoder defective
· Eliminate the blocking
· Check /
exchange the encoder cable
· Exchange the sewing motor
1342
-
1344
Sewing motor fault
Internal fault
· Switch the machine off/on again
· Software update
· Information to DA-Service
2101 Step motor X-axis timeout
reference
· Cable to the reference switch
faulty
· Reference switch defective
· Exchange the cable
· Exchange the reference switch
2102 · Step motor X-axis
Current supply fault
· Step motor X-axis
blocked
· Encoder cable not
connected/defective
· Encoder defective
· Eliminate the blocking
· Check / exchange the
encoder cable
· Exchange step motor X-axis
106