29.7 Menu item test functions / Test program sewing sequence
29.7.1 Menu item stop
In this menu item the sewing sequence is stopped at various steps.
This facilitates the testing and adjusting of the automate.
The following is the meaning values set:
Caution Risk of injury !
The testing program serves only for the checking of cycles and
functions. Maintenance and setting work should not be conducted
when running the testing program.
0= normal sewing cycle, the testing program is turned off.
1= the sewing cycle is stopped after switching the valves of the
thread catcher on.
2= the sewing cycle is stopped after switching the valve of the
respective thread trimming system on.
3= the sewing cycle is stopped after switching each valve on.
29.7.2 Menu item reference start
In this menu item it is possible to start a reference run.
This testing program is particularly helpful for the setting of the sewing
machine.
Caution: Danger of injury !
Exercise utmost caution when making the output test with
the machine running.