29.4.3 Menu item thread monitor (Thread mon.)
In this menu the needle thread monitor is set.
The set value means:
0 = Thread monitor switched off
1 … 14 = Number of stitches after which the sewing
process is aborted because of thread breakage
Input: 0 … 14
Standard: 7
29.4.4 Menu item duty cycle of cutting block (Cut. time)
The duration of the incision can be set individually so that the material
to be processed is cut open accurately and no longer than required.
Input: 200 … 600
Standard: 200