Display Unit iDT-002
MT-91E-A01-B
Page 3
TECHNICAL DATA
2
2 TECHNICAL DATA
2.1 Display unit iDT-002 specifications
Applicable pump
STP-iXA2206/iXA3306 series
STP-iXA4506 series
STP-iX3006 series
STP-iX457/iXU457 series
STP-iS1607/iS2207series
STP-iXA3307 series
STP-iXA4507 series
Input voltage
12 Vd.c or 24 Vd.c (supplied from STP
pump, or power supply unit iPD-240-24V)
Allowable input voltage fluctuation
± 10 %
Consumption current
300 mA maximum
Operating ambient temperature
0 to 40 °C (32 to 104 °F)
Operating ambient relative humidity
30 to 95 % (non condensing)
Storage temperature
-25 to 55 °C (-13 to 131 °F)
Storage ambient relative humidity
10 to 95 %
Mass (except the optional accessory)
0.6 kg (1.32 lb)
Dimensions
Refer to Figure 1
Operation switch
START
(Push-button switch•Green)
STOP
(Push-button switch•Dark Grey)
RESET
(Push-button switch•Grey)
SELECT
(Push-button switch•Grey)
UP
(Push-button switch•Grey)
DOWN
(Push-button switch•Grey)
ENTER
(Push-button switch•Grey)
Panel indication LED
ACCEL.
(Green LED)
NORMAL
(Green LED)
BRAKE
(Green LED)
POWER
(Green LED)
FAILURE
(Red LED)
Panel display
LCD
(2 lines of 16 characters)
Input/Output terminal
X1
(5 pins)
X2
(6 pins)
X3
*1
(Option)
For direct connection of iDT-002 to STP-
iX457/iXU457
(9 pins)
STP-Link
(8 pins)
*1 A version with X3 connectors can also be available. Contact Edwards for further information.