OPERATION
4
4.7.16 Setting procedure
See Figure 17 to Figure 22.
1. Press the "UP" and "SELECT" switches simultaneously to enter Parameter Set Mode while the
Operation Mode is displayed.
The available menu items (Section 4.7.1 through 4.7.14 above) are displayed in order.
2. Press the "UP" switch to go to the next parameter, and press the "DOWN" switch to display the
previous one.
3. Press the "ENTER" switch to set the new parameter and to enter the next menu. However, note
that the new parameter is not saved until it is stored in No.6.
4. When just want to move to the next menu without setting the parameter, press the “SELECT”
switch.
5. Press the "UP" or "DOWN" switches to change the parameter, and set it with the "ENTER"
switch.
6. "STORAGE NO" is displayed on the preservation menu. Select "YES" with the "UP" or "DOWN"
switches and press "ENTER" to store the parameter. The message "STORAGE IN PROGRESS"
is shown, which indicates saving the parameters in progress. When the storage succeeds,
"STORAGE OK" is displayed. If the saving fails, "STORAGE NOT OK/TIME OUT" is displayed.
7. When pressing the "SELECT" switch in the state of "STORAGE NOT OK/TIME OUT" displayed,
the preservation menu is displayed. Try to store it again.
8. Press the "SELECT" switch when the state "STORAGE OK" is displayed to enter the date/time
setting menu. The date and time currently set are displayed. Press the "ENTER" switch to enter
the year setting menu. If not want to set a date, press the "SELECT" switch and return to the
operation mode.
9. The year can be changed with the "UP" or "DOWN" switch. Press the "SELECT" or "ENTER"
switch to enter the month setting menu. However, note that the change of year is not saved yet.
10. In the same way of setting the year, set the date, hour, and minute in order.
11. The LCD shows the “date/time” and "ENTER to Cancel" in the confirmation menu. If there were
some mistakes in the set values, press the “ENTER” to cancel the setting date and time. And
then set date and time from No.8 again.
12. After confirming the date/time on the confirmation menu, change the “cancel” to "apply" with the
"UP" or "DOWN" switch and then press the "ENTER" switch.
Note: If no switch is pressed for approximately 1 minute, the display will automatically revert to the
Operation mode. In this case, the changed settings are not saved.
Note: When the communication error is detected, the STP pump cannot enter the Parameter Set
Mode. The STP pump will automatically return to the Operation Mode when the
communication error occurs in the Parameter Set Mode.
Note: When the data cannot be obtained, each menu displays "no data," and the parameter is not
can be changed.