4.6 Confirmation mode
The confirmation Mode allows checking the following items of the STP pump.
The available item groups 1 through 5 in Table 7 and Table 8 are displayed in order.
The active functions is depending on the STP pump models. The unavailable items are displayed as
"Unsupported”. The items that cannot be changed depending on the STP pump models are
displayed as "Unchangeable".
iXA2206
iXA3306
iXA4506
iX3006
series
Model /
version
information
Control unit software version
Motor driver software version
Built-in clock (value is
constantly updated)
Total running hours of STP
pump
(total hours of acceleration,
normal operation, and
deceleration)
Total running hours of STP
control unit (total hours of power
on state including levitation
state).
Number of starts
(total number of start operation)
Touch down bearing damage
Set value /
measured
value
Pump motor temperature
measurement (value is
constantly updated)
Control unit temperature
measurement (value is
constantly updated)
Motor current measurement
(rate to the maximum rated
current, value is constantly
updated)
Table 7 - Confirmation Mode items (1/2)
*1 The TMS temperature setting cannot be changed on some models in the iXA3307/iXA4507 series.