Display Unit iDT-002
MT-91E-A01-B
Page 47
OPERATION
4
Note: When the communication error is detected, the STP pump cannot enter the Manual
Operation Mode. The STP pump will automatically return to the Operation Mode when the
communication error occurs in the Manual Operation Mode.
Note: If the communication cable of the display unit iDT-002 is disconnected, the TMS maintains
output. In order to change the output, connect the display unit iDT-002 to the pump again
and enter the Manual Operation Mode.
Note: When the TMS temperature attains at the TMS high-temperature abnormal detection
threshold, the TMS heater output turns "OFF" automatically for safety.
Manual Operation
TMS Heater OFF
Manual Operation
TMS Heater ON
Levitation
NORM:*****rpm
・・・・・
A
B
Manual Operation
TMS Heater Auto
Manual Operation
TMS Valve Close
Manual Operation
TMS Valve Open
C
Manual Operation
TMS Valve Auto
Manual Operation
Vent Valve Close
Manual Operation
Vent Valve Open
D
Manual Operation
Vent Valve Auto
UP
DOWN
DOWN
SELECT
+
SELECT
UP
DOWN
SELECT
ENABLE
DISABLE
SELECT
UP
DOWN
ENABLE
DISABLE
ENABLE
DISABLE
A.
Operation mode
B.
TMS heater output operation
C.
TMS water valve output operation
D.
Vent Valve output operation
Figure 23 - Manual operation mode operation method