The connector supplies the power to the vent valve or fan connected to the 3pins. The
connect
or mang plug is shown in Figure: Controller connector showing pin numbers,
with the polarity of the pins marked, when the vent valve or fan is set to on.
The 24 V d.c. output on the controller connector is protected from the overload or short
circuit to 0 V d.c. / 24 V d.c. Rtn / chassis. The output supplies the current given in Table:
Controller technical data. For higher currents, the output voltage will decrease and can
set to o to limit the current.
Table 12
Controller technical data
Descripon Data
Connector plug Phoenix part number FKMC1881338
Voltage output 24 V d.c. -25%, +10% (18 V d.c. to 26.4 V d.c.)
Current output 500 mA
Figure 10 Controller connector showing pin numbers
Pin number Signal Polarity
1 24 V d.c. Out +
2 Chassis
3 24 V d.c. Rtn -
3.11 Indicator LED's
The pump has three indic
ator LED's, shown in Figure: Controller status informaon.
Table 13
Indicator LED’s
LED Descripon
Normal LED
The green LED stays when the rotaonal speed of the pump is more
than the normal speed seng, irrespecve of the acceleraon or de-
celeraon of the pump.
04/2022 - ©Edwards Limited
Page 35B80000880_G
B80000880_G - Technical data