Command ? S 8 5 1 cr
The reply is as follows (where string 1 is the pump type, string 2 is the DSP sowar
e
version number and string 3 is the designated full speed of the pump (in
revoluons per second)):
Reply = S 8 5 1 sp String 1 ; String 2 ; String 3 ; cr
Send the query that follows to nd out the boot loader sowar
e version:
Command ? S 8 6 8 cr
The reply is as follows (where, string 1 is the boot loader soware version number):
Reply = S 8 6 8 sp String 1 cr