Loading...
STP-iX455/iXL455 Series Instruction Manual
9-35
Operation
Table 9.11 Warning Value Bit Assign
Bit
Warning message 16-bits hex value
0
[System reservation]
0001
1
[System reservation]
0002
2 WARNING: Damage Limit 0004
3 WARNING: Imbalance X_H 0008
4 WARNING: Imbalance X_B 0010
5 WARNING: Imbalance Z 0020
6 WARNING: Pump Run Time Over 0040
7
[System reservation]
0080
8
[System reservation]
0100
9
[System reservation]
0200
10
[System reservation]
0400
11
[System reservation]
0800
12
[System reservation]
1000
13
[System reservation]
2000
14
[System reservation]
4000
15
[System reservation]
8000
Example:
Pump operation mode
: 01
hex
= 1 = Levitation
WARNING being
detected
: 000C
hex
= 0004
hex
OR 0008
hex
=
2 warnings of "WARNING: Damage Limit",
"WARNING: Imbalance X_H"
The number of error : 02
hex
= 2 errors
Error 1
: 0D
hex
= 13 = Disturbance Xh
Error 2 : 0F
hex
= 15 = Disturbance Xb
Error 3 to 79 : 00
hex
= No error detected
Parameter
1 2
ASCII 0
1
0
0
0
C
HEX 30
31
30
30
30
43
Parameter
3 4 5 6 7 8 9 10 11 12
ASCII 0
2
0
D
0
F
0
0
0
0
0
0
0
0
0
0
0
0
0
0
HEX 30
32
30
44
30
46
30
30
30
30
30
30
30
30
30
30
30
30
30
30
Parameter
13 14 15 70 71 72
ASCII 0
0
0
0
0
0
[Omitted] 0
0
0
0
0
0
HEX 30
30
30
30
30
30
30
30
30
30
30
30
Parameter
73 74 75 76 77 78 79 80 81 82
ASCII 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
HEX 30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30

Table of Contents