STP-iX455/iXL455 Series Instruction Manual
9-39
Operation
Table 9.12 Parameter Setting Value
Parameter
Item Setting range
1 Remote operation mode setting
I/O REMOTE (X2): 01
hex
COM1 (X3): 02
hex
COM2 (X5 STP-Link): 05
hex
COM3 (Power supply unit): 06
hex
COM4 (Communication unit):
07
hex
3
Vent valve
Enable/Disable setting
ENABLE00
hex
DISABLEFF
hex
4 Vent valve starting speed setting
10 to 80%
(0A
hex
to 50
hex
)
5 Vent valve running time setting
5 to 600sec.
(0005
hex
to 0258
hex
)
7
Damage Limit Warning
Enable/Disable setting
ENABLE00
hex
DISABLEFF
hex
8
Pump Runtime Over Warning
Enable/Disable setting
ENABLE00
hex
DISABLEFF
hex
9
Pump Runtime Over Warning
Hours setting
0 to 300,000×100 hours
(00000000
hex
to 000493E0
hex
)
10
Imbalance Warning
Enable/Disable setting
ENABLE00
hex
DISABLEFF
hex
12
Serial communication
time out setting
0 to 30,000 sec. (0000
hex
to
7530
hex
)
Round down to the 60 seconds
Set to 0 to disable function