STP-iX455/iXL455 Series Instruction Manual
9-33
Operation
9.4.11 ReadSpeedSetPoint
Function:
Reads the "Speed Set Point" value.
This value is the same as "ReadSetPoint" parameter 1 (Speed Set Point).
Transmission Frame:
PCSIM
Stx
0
0
1
? h
Etx
LRC
SIMPC
Ack
PCSIM
Ack
SIMPC
Stx
0
0
1
Sp
h
Parameter 1
Etx
LRC
Parameter Item Data format Remark
1
Speed Set Point
(Unit: Hz)
16-bits hexadecimal
coded ASCII
Example:
Speed Set Point: 0320
hex
= 800 Hz = 48,000 rpm
Parameter
1
ASCII 0
3
2
0
HEX 30
33
32
30