• On Grid EOD Voltage(V): The inverter will stop discharging the battery at this voltage and
will use AC to power loads. When battery voltage is > (EOD Voltage +3V), the inverter will
switch back to battery discharge mode.
• On Grid EOD SOC(%): The inverter will stop discharging the battery at this SOC and will use
AC to power loads. When battery SOC is > (EOD SOC+10%), the inverter will switch back to
battery discharge mode.
7.5 OTHER SETTING
• Batt Volt Sample Disable: Set to Internal, External or Both Available.
• Fan 1 Max Speed(%): This sets cooling fan 1 max. speed. Range is 50-100%.
• Fan 2 Max Speed(%): This sets cooling fan 2 max. speed. Range is 50-100%.
7.6 RESET
• All to Default: This resets all settings to factory default values.
Be sure to keep track of the settings and what changes need to be made before
outputting power from the inverter