Operating manual - Fan CF-C Operation of the fan
2004930 10.19/0.2 www.elektror.com 61 of 84
- a sudden change occurs in the noise level,
- and / or shocks.
- If required, align or replace the clutch.
Electric motor
When checking the electric motor, pay attention to operational noises and smooth running X
If necessary, remove dust deposits from the electric motor. X
Protection
Check the protection to confirm cleanliness, completeness and reliable operation. X
- If necessary, clean contaminated surfaces. X
- If necessary, have the restoration of operational readiness. X X X
Descriptions and information
plates
Check their stable fixing and readability. X X X
- If necessary, clean illegible elements. X
- If necessary, install detached elements. X
Electric wires, connections
and bolted joints
Check their damage, tightness and stable fixing. X
- If necessary, clean illegible elements. X
- If necessary, install detached elements. X
Compensators and
deflectors
Check compensators in case of process changes. X
Condensate drain pipe
Check if water has accumulated in the housing. X
- If necessary, open the condensate drain pipe and allow the water to drain. X