Operating manual - Fan CF-C Operation of the fan
2004930 10.19/0.2 www.elektror.com 67 of 84
EN
discs, by means of which the amount of grease in the
bearing is precisely
adjusted. Excess grease remains in
the bearing housing.
After about a 10. lubrication with grease given in
Table 22
"Lubrication intervals and grease quantities" with the
assignment to a specific bearing, the old grease must be
co
mpletely removed from the bearing housing and the
housing must be filled with new grease.
When lubricating, remember to use the amount of grease
shown in the above table (it is necessary to accurately
weigh this amount).
Lubrication intervals
Table 22: Lubrication intervals and grease quantities for bearing blocks
Housing Slide
bearing
Fixed
bearing
Lubrication intervals (during working hours) First or
subseque
nt filling
Amount of
grease
Grooved
ball
bearing
C3
Grooved
ball
bearing
C3
≤ 3600
> 3000
3000
> 1800
1800
> 1500
1500
> 1000
≤ 1000 (g) (g)
BL25
6305
6305
5400
6800
9100
13600
14400
50
5
BL30 6306 6306 4800 6000 8000 12000 12700 60 5
BL35 6307 6307 4300 5400 7200 10800 11400 80 5
BL40
6308
6308
3800
4700
6300
9500
10000
110
10
BL50 6310 6310 2900 3700 4900 7400 7800 190 10
BL60 6312 6312 2300 2900 3800 5700 6000 300 15
BL75 6315 6315 1600 2000 2600 3900 4100 590 20
BL80 6316 6316 1400 1700 2300 3400 3600 700 20
BL95 6319 6319 900 1200 1600 2400 2500 1150 30
BL100 6320 6320 800 1000 1300 2000 2100 1450 35
BL110 6322 6322 300 400 500 800 1600 1900 40