Operating manual - Fan CF-C Operation of the fan
2004930 10.19/0.2 www.elektror.com 63 of 84
CP – cleaning personnel E – qualified electrotechnician
M – maintenance mechanic C - coordinator
Maintenance every 3 months
Element Activity CP E M C
The fan as a whole
The fan as a whole should be checked in order to exclude abnormal operating phenomena, noise during
operation, heating up, occurrence of odours and leaks
X
- Check all bolt connections to confirm their proper tightening, or tighten the bolts. X X
Electric motor
Electric motor
Check cleanliness and stable fixing. X
- If necessary, clean the impeller cover from impurities. X
- If necessary, clean the electric motor from dirt. X
- If necessary, fasten the loose motor. X
Compensators and
deflectors
Compensators and
deflectors
- Check the compensators and tighten the fixing screws if necessary. X
- In case of wear, the compensators must be replaced. X