EasyManua.ls Logo

Elma Elmasolvex VA - 4.2 Attaching Protective Grilles

Elma Elmasolvex VA
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Before the initial commissioning
22
BA_Elmasolvex_VA_EN_Vers.05.2018 © Elma Schmidbauer GmbH
Fire and explosion hazard!
Ignitable vapours of the cleaning and rinsing media can escape
in the case of improper operation without exhaust air tubes /
without activated carbon unit and when changing the cleaning
liquids.
Smoking and open ignition sources are prohibited in the
cleaning machine surroundings.
Maximum one day's requirement of the solvents used is
permitted to be stored in the surroundings of the cleaning
machine at a minimum distance of 3 m from the cleaning
machine.
4.2 Attaching protective grilles
The protective grilles in front of the media tanks are not
attached when the cleaning machine is delivered.
Procedure for attaching protective grilles:
1. Insert the two protective grilles with the carriage
(Fig. 4.2.1.B) in each case from above into the guide rails.
2. Unscrew the grub screws (Fig. 4.2.1.A) at the upper ends of
the guide rails by approx. 2 turns.
3. Place the plastic cap (Fig. 4.2.1.C) on to the edge of the
guiding rail.
Fig. 4.2.1 Protective grilles guide mechanism
DANGER
B
C
A

Table of Contents

Related product manuals