Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide 199
Issue Number: 5 www.controltechniques.com
Figure 11-29 SM-I/O Lite analog I/O logic diagram
x.48
0.00
Default
source
Pr
0.00
21.51
Source
x.49
Scaling
x.39
Mode
Voltage
or current
0.XX
0.XX
Key
Read-write
(RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default settings
x.40
Level
x.03
Current loop
loss indicator
x.41
Scaling
x(-1)
x.42
Invert
x.43
Destination
0.00
50.99
Default
destination
Pr
0.00
200R
0V
Current
mode and
protection
x.38
Mode
T2 Analog Input 1